NeuroCenter® EEG Instructions for Use

Version 3.0.5 - 2017-10-31

Bug

NCEEG-11 Filter artefact is shown in static viewer when recording \(both begin and end\)

NCEEG-20 Analyses don't restart after temporary suspending the registration.

NCEEG-42 When using a BPF filter and setting the interval to >30 secs, the EEG is distorted

NCEEG-78 Navigator shows active session as 1 even when last viewer has been closed

NCEEG-95 Crash when not indicating TMSi connection type

NCEEG-97 Crash when selecting protocol which is already running in another session

NCEEG-98 Impedance check is available even when amplifier doesn't support impedance

NCEEG-106 Closing the review window when recording, hides the montage labels on the real-time view.

NCEEG-118 Application crashes when elements of the recording protocol are undefined.

NCEEG-121 Default impedance during impedance measurement mode should follow the selected impedance in the protocol \(it is now 0\)

NCEEG-122 In the protocol settings the impedance is shown as Ohm instead of kOhm.

NCEEG-128 Join viewer doesn't work when one of the viewers is hidden

NCEEG-129 Program freezes when recording @ 4KHz

NCEEG-130 Opening a set of files as part of a container, doesn't always pick up the correct files

NCEEG-140 Channels FC3 and C3 show up undefined in montage

NCEEG-143 Recording can proceed without selecting a protocol

NCEEG-144 Support for unicode names in EDF\+ files

NCEEG-157 VLDelta doesn't seem to be correctly calculated on 4KHz Refa amplifier

NCEEG-159 Calendar & List icons in review seems too small

NCEEG-160 Empty analysis groups show up in analysis overlay \(review\)

NCEEG-161 Forms icon should be hidden

NCEEG-162 Dutch translation issue in settings welcome screen \(categorie -> category\)

NCEEG-163 Real-time annotations don't work very well

NCEEG-167 No RT data shown from TMSi amplifier plugin

NCEEG-168 PureEEG filter needs to be faster \(needs now full initialization\)

NCEEG-172 AITDistributor needs killing when selecting a different EEG file

NCEEG-174 Filtering in RT mode only filters the real-time signal and not the previously recorded one

NCEEG-175 Starting analyses before pressing the record button, doesn't start the analyses

NCEEG-176 Switching montage in RT mode crashes the application

NCEEG-177 Average filter activated in Review mode disables the other filters

NCEEG-179 Created / Modified not inserted using NeuroCenter PDMS export plugin

NCEEG-202 Opacity effect \(fade-out\) creates unusable interface with Qt version >= 5.9

NCEEG-210 Performing analyses on 10-10 registrations triggers a crash

Story

NCEEG-4 Display actual time \(clock\) during registration.

NCEEG-21 Make more clear that there is no analysis value in discontinuous recordings gaps.

NCEEG-54 NeuroCenter PDMS Export plugin

NCEEG-57 Ignore missing fields in the signal files which leads to not able to view the file.

NCEEG-63 Create downloadable demonstration data

NCEEG-73 The wizard widgets should not suggest random access to each step from the step list.

NCEEG-84 Adjust spectrum analysis and BSI routine to match Matlab / Octave behaviour

NCEEG-85 Subscription based licensing solution

NCEEG-87 Disable viewer features when in impedance measurement modus

NCEEG-104 Compatibility with BrainRT EDF\(\+\) files

NCEEG-116 Integration of Encevis modules \(Spike & Seizure detection and Artefact Rejection\)

NCEEG-120 Adjust recording voltage ranges per channel, instead of per group of channels \(EEG / AUX\)

NCEEG-127 Annotation timer should not display msecs

NCEEG-134 Possibility to disable and erase the analysis cache

NCEEG-154 Provide support for EDF\+D files with discontinuity on first datarecord.

NCEEG-189 Add support for the EEGO mini amplifier

NCEEG-208 Implement F11 shortkey for full screen toggle

Change

NCEEG-141 Screen decimation filter should be able to ignore user-defined channels

NCEEG-185 Use thread separation on static data display when recording.

NCEEG-203 Refa 64 channel amplifier doesn't work @ 2KHz

NCEEG-204 Parameterize the subject ID field